Aquamicron

Aquamicron

 

Coulometric Reagents

AQUAMICRON® AXI
AQUAMICRON® AX 
AQUAMICRON® AX01
AQUAMICRON® AS
AQUAMICRON® AKX
AQUAMICRON® CXU
AQUAMICRON® FLS

Volumetric Reagents

AQUAMICRON® Titrant SS-Z 1mg
AQUAMICRON® Titrant SS-Z 3mg
AQUAMICRON® Titrant SS-Z 5mg
AQUAMICRON® Solvent GEX
AQUAMICRON® Solvent OLX
AQUAMICRON® Solvent OLII
AQUAMICRON® Solvent KTX
AQUAMICRON® Solvent SU

AQUAMICRON® Titrant SS 1mg
AQUAMICRON® Titrant SS 3mg
AQUAMICRON® Titrant SS 10mg
AQUAMICRON® Solvent ML
AQUAMICRON® Solvent MS
AQUAMICRON® Solvent CM
AQUAMICRON® Solvent CP
AQUAMICRON® Solvent PP
AQUAMICRON® Solvent PE
AQUAMICRON® Solvent FM
AQUAMICRON® Solvent ME

For Coulometric Titration

 

AQUAMICRON® Water Standard 0.1

 

AQUAMICRON® Water Standard 0.2

 

AQUAMICRON® Water Standard 1

 

AQUAMICRON® Check Solution P

For Volumetric Titration

 

AQUAMICRON® Water Standard 10

 

AQUAMICRON® Standard Water/Methanol

For Vaporization Method



AQUAMICRON® Solid Water Standard

AQUAMICRON Series

 

There are two types of coulometric reagents: the anolyte (generating solution),which is placed in the anode chamber of the electrolysis cell, and the catholyte (counter electrolyte), which is placed in the cathode chamber. There are also special anolyte for use with ketones, lower carboxylic acids and silicone oils. AQUAMICRON® can be used in coulometric moisture measurement systems sold by various companies, and it has a worldwide reputation for excellent performance.

AQUAMICRON Series 

 

There are two types of coulometric reagents: the anolyte (generating solution),which is placed in the anode chamber of the electrolysis cell, and the catholyte (counter electrolyte), which is placed in the cathode chamber. There are also special anolyte for use with ketones, lower carboxylic acids and silicone oils. AQUAMICRON® can be used in coulometric moisture measurement systems sold by various companies, and it has a worldwide reputation for excellent performance.

AQUAMICRON® Series

Product name

Use

Specification

Package

http://www.mcckf.com/english/common_img/cou_01.gif

AXI

*AXI [For frit or fritless type cell, equivalent to FLS]
*AXI, AX & AX01[For General-use] 
Organic solvents, Inorganic chemicals, Oiles, Petroleum products, Various kind of gases, etc.

Moisture
maximum
0.15mgH2O/mL

500mL

AX

AX01

100mL

AS

[For Oils]
Naphtha, Gasolone, Diesel oil, Electrical insulation oil, etc.

Moisture
maximum
0.15mgH2O/mL

500mL

AKX

[For Ketones]
Ketones. Silicone oils. Low carboxylic acids, etc.

Moisture
maximum
0.15mgH2O/mL

500mL

CXU

[Catholyte]
Both AX and AS and AKX available to combine with

Moisture
maximum
0.6mgH2O/mL

5mL
x10/case

FLS

[For fritless type cell]
Organic solvents, Inorganic gases, etc.

Moisture
maximum
0.15mgH2O/mL

500mL

 

AQUAMICRON® AXI/CXU or AX/CXU
Use:General samples
Characteristics: 

 

Minimal environmental contamination

Does not include carbon tetrachloride or chloroform

 

Wide range of applications

Suitable for petroleum products

 

 

Can be used with moisture vaporization method
(When using AQUAMICRON® AX or AXI in a moisture vaporization method, replenish the vaporized portion with methanol.)

 

High quality, high performance

Excellent reputation for accurate moisture measurement and end-point stability
Approximately 800mg of moisture can be measured per 100mL of AQUAMICRON® AX or AXI, and approximately 150mg per 5mL of AQUAMICRON® CXU

 

Easy to use

These products can be used in the existing coulometric moisture measurement system

AQUAMICRON® AS/CXU
Use:General samples
Characteristics: 

 

Wide range of applications

Especially suitable for oils, petroleum products

 

High quality, high performance

Excellent reputation for accurate moisture measurement and end-point stability.

 

 

Approximately 800mg of moisture can be measured per 100mL of AQUAMICRON® AS, and approximately 150mg per 5mL of AQUAMICRON® CXU.

 

Easy to use

These products can be used in the existing coulometric moisture measurement system.

AQUAMICRON® AKX/CXU
Use:Ketones, lower carboxylic acids, some aldehydes (aromatics)
Characteristics:

 

Minimal environmental contamination

Does not include chloroform or methyl cellosolve

 

Wide range of applications

Suitable for ketones, lower carboxylic acids and some aldehydes

 

High quality, high performance

Accurate moisture measurement, good end-point stability

Approximately 300mg of moisture can be measured per 100ml of AQUAMICRON® AKX, and approximately 100mg per 5mL of AQUAMICRON® CXU (when used with AQUAMICRON® AKX).

 

Easy to use

These products can be used in the existing coulometric moisture measurement system.

AQUAMICRON® AXI or FLS
Use:Suitable for alcohols, esters, benzene, toluene, inorganic gases, etc.
Characteristics:

 

Easy to use

AQUAMICRON® AXI or FLS is a single-solution type reagent. It should be used in single-solution electrolytic cells without diaphragm, fritless type cell.

Can be used with moisture vaporizati on method(When using AQUAMICRON® AXI or FLS in a moisture vaporization method, replenish the vaporized portion with methanol.)

 

Easy to use

Ceramic diaphragm is not used, therefore it is easy to maintain electrolytic cell in good condition.

 

 

Aquamicron